Can the existing Full Function Test Kit (FFTK) be used for testing the new Compact NSX MCCB?
Compact NSX can be tested with a new dedicated test kit, Maintenance case reference TRV00910. This TRV00910 test kit works in association with the...
Can the same mechanical interlock for LC1FL44 contactor be used for mechanical interlock of the new equivalent LC1F6304 contactor.
Yes, the same mechanical interlock LA9FL970 can be used for both the old LC1FL44 as well as for new equivalent LC1F6304 contactors. This is a horizontally...
How to display numeric value 123456789.45 in comma separated format on graphics page in Vijeo Citect?
Use following VBA script to convert numeric value to comma separated format. Function Test(varx As Variant) As Variant Test = Format(varx,"###,###,###0.00")...
What are the recommended Cable Sizes and the Tightening Torque values for the Multi9 Final Low Voltage (FLV) range of products?
The recommended Cable Sizes and the Tightening Torque values for the Multi9 Final Low Voltage (FLV) range of products is given in the attached document....
What is the difference between 31088 and 31097 key locking devices.
31097 key locking device is used for the Single Handle Source Changeover Assembly in which different type off cam is used. These cams are to be ordered...
Can the OA1 output of Tesys U be used with multi function unit to drive a separate motor contactor.
Output OA1 for Tesys U with base contactor (LUB**) is only used to drive the contactor embedded inside the TesysU contactor base LUB.   In order to use...
How to configure and setup Scada Pack E - series RTU over Modbus TCP?
Follow steps as below :- -  Configure scadapack RTU from E-configurator with settings as shown .    Configure some analog points like derived point...
What is the new tag point count licensing in Citect SCADA V7.0 ?
In CitectSCADA 6.10 or earlier, multiple tags that share the same I/O device address will be counted as a single I/O point. This is calculated at...
How to reset Trio radio like J series to factory default incase IP address or other settings are unknown ?
If the radio settings become unknown then a factory reset is required. A factory default can be initiated by applying DC power to the radio (wait...
What is the Mean time between failures (MTBF) for 140CPU67861 in hours ?
The MTBF figures in hours at different temperature and continuous operation are as follows: 140CPU67861                    Mtbf 30° Continuous operation...