Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    03050 Product picture Schneider Electric

    Range: Prisma

    Functional units

    03050

    03050 Product picture Schneider Electric
    Range: Prisma

    Functional units

    03050

    mounting plate NSX/CVS/vigi/INS 250 vertical fixed toggle

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range
      Prisma
      range compatibility
      Prisma P
      Prisma G
      Prisma Pack 250
      product or component type
      Mounting plate
      accessory / separate part category
      Installation accessory
      installed device
      Compact : fixed INS250 - control: direct front rotary handle - vertical installation
      Compact : fixed INV250 - control: direct front rotary handle - vertical installation
      Compact : fixed NSX100...160 with earth leakage protection - control: toggle - vertical installation
      Compact : fixed NSX250 with earth leakage protection - control: toggle - vertical installation
      Compact : plug-in NSX100...160 with earth leakage protection - control: toggle - vertical installation
      Compact : plug-in NSX250 with earth leakage protection - control: toggle - vertical installation
      Compact : fixed NSX100...160 without earth leakage protection - control: toggle - vertical installation
      Compact : fixed NSX250 without earth leakage protection - control: toggle - vertical installation
      Compact : plug-in NSX100...160 without earth leakage protection - control: toggle - vertical installation
      Compact : plug-in NSX250 without earth leakage protection - control: toggle - vertical installation
      Easypact : fixed CVS100...160 without earth leakage protection - control: toggle - vertical installation
      Easypact : fixed CVS250 without earth leakage protection - control: toggle - vertical installation
      Compact : fixed INV100 - control: direct front rotary handle - vertical installation
      Compact : fixed INV160 - control: direct front rotary handle - vertical installation
      Compact : fixed INV200 - control: direct front rotary handle - vertical installation
      Easypact : fixed CVS100...160 with earth leakage protection - control: toggle - vertical installation
      Easypact : fixed CVS250 with earth leakage protection - control: toggle - vertical installation
      poles description
      1 x 3P : fixed : INS250 vertical installation
      1 x 3P : fixed : INV250 vertical installation
      1 x 4P : fixed : INS250 vertical installation
      1 x 4P : fixed : INV250 vertical installation
      1 x 3P : fixed : INV100 vertical installation
      1 x 3P : fixed : INV160 vertical installation
      1 x 3P : fixed : INV200 vertical installation
      1 x 4P : fixed : INV100 vertical installation
      1 x 4P : fixed : INV160 vertical installation
      1 x 4P : fixed : INV200 vertical installation
      1 x 3P : fixed : NSX100...160 vertical installation
      1 x 3P : fixed : NSX250 vertical installation
      1 x 3P : fixed : CVS100...160 vertical installation
      1 x 3P : fixed : CVS250 vertical installation
      1 x 4P : fixed : NSX100...160 vertical installation
      1 x 4P : fixed : NSX250 vertical installation
      1 x 4P : fixed : CVS100...160 vertical installation
      1 x 4P : fixed : CVS250 vertical installation
      1 x 3P : plug-in : NSX100...160 vertical installation
      1 x 3P : plug-in : NSX250 vertical installation
      1 x 4P : plug-in : NSX250 vertical installation
      1 x 4P : plug-in : NSX100...160 vertical installation
      Complementary
      enclosure/cubicle description
      Floor-standing duct - width 300 mm
      Wall-mounted duct - width 300 mm
      Cubicle - width 400 mm, depth 400 mm
      Pack enclosure - width 300 mm
      number of vertical modules [50 mm]
      9 module(s) : CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      9 module(s) : CVS250 without earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : CVS250 without earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : CVS250 without earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      9 module(s) : INS250, direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : INS250, direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV100, direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV100, direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV160, direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV160, direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV200, direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV200, direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV250, direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : INV250, direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : NSX100...160 without earth leakage protection , front connection in 400 mm Wide cubicle
      9 module(s) : NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      9 module(s) : NSX250 without earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      9 module(s) : NSX250 without earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      9 module(s) : NSX250 without earth leakage protection , front connection in 400 mm Wide cubicle
      9 module(s) : NSX250 without earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      13 module(s) : CVS100...160 with earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      13 module(s) : CVS100...160 with earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      13 module(s) : CVS250 with earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      13 module(s) : CVS250 with earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      13 module(s) : NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      13 module(s) : NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      11 module(s) : NSX100...160 with earth leakage protection , front connection in 400 mm Wide cubicle
      13 module(s) : NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      13 module(s) : NSX250 with earth leakage protection , direct with long terminal shield in 300 mm Wide floor-standing duct (cable coming from top or bottom of enclosure)
      13 module(s) : NSX250 with earth leakage protection , direct with long terminal shield in 300 mm Wide wall-mounted duct (cable coming from top or bottom of enclosure)
      11 module(s) : NSX250 with earth leakage protection , front connection in 400 mm Wide cubicle
      13 module(s) : NSX250 with earth leakage protection , direct with long terminal shield in 300 mm Wide Pack enclosure (cable coming from top or bottom of enclosure)
      condition of use
      Need additional plate (1M high) when installation of device is in vertical
      height
      250 mm
      product weight
      0.54 kg
      surface finish
      Matt
      Smooth
      protective treatment
      Electrophoresis treatment and hot-polymerised polyester epoxy powder
      colour
      White RAL 9001
      Environment
      standards
      IEC 61439-2
      product certifications
      ASEFA
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  0807  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Available
      Product end of life instructions
      Need no specific recycling operations
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      Catalogue
      Date
      Size
      Add to My Documents
      Catalogue Prisma P 2014-15
      Date 7/18/18
      Size 85.6 MB
      Date 7/18/18
      Size 103.4 MB
      CAD
      Date
      Size
      Add to My Documents
      M.PL.V.FIX.NS TOG.INS250 W250
      Date 8/8/13
      Size 507.9 KB
      Date 8/8/13
      Size 314.8 KB
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 5/25/18
      Size 3.1 MB
    • Technical FAQs

      No results found
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.